Categories
Vascular Accessories

Introducer sheath

TRANS INTRO

Introducer sheath

OVERVIEW

Sheaths are intended to be inserted percutaneously into a vessel to facilitate the entire interventional procedure.

Product Features:

  • rotating suture collar that facilitates greater procedural flexibility. It stays in place better and allows more patient movement.
  • kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer for improved bendability and support. It is also less prone to kinking, cost-effective and reliable.
  • Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered. This results in smooth insertions and may cause less damage upon entry.
  • Unique cross-cut valve which maintains uncompromised hemostasis to avoid bleeding & air aspiration.
  • Smooth sheath-to-dilator transition and optimally tapered dilator enable to reduce penetration resistance.
  • Extremely thin radiopaque wall with anti-kinking sleeve for excellent catheter handling.
  • Dilator internal tip diameter equals to mini guidewire external diameter.
  •  

Ordering Information:

Categories
Vascular Accessories

Inflation device

TRANS ID

Balloon Inflation device

OVERVIEW

Trans ID offers a simple solution for balloon inflation and deflation.

Product Features:

  • Maximum pressure of 30 atm
  • 20 ml clear syringe barrel with smooth moving plunger
  • Self-locking mechanism for easy locking as well as gradual and rapid pressure release
  • Grip Finger & Ergonomic handle for better grip
  • Precision manometer shows accurate pressure
  • Wide range of products
  • Available in all 3 variants:
    – Premium Type
    – Normal Type
    – Gun Type

Trans ID - Premium Type

Trans ID - Gun Type

Trans ID - Normal Type

Categories
Vascular Accessories

DIAGNOSTIC CATHETER

DIAGNOSTIC CATHETER

Trans Angio | Trans Angio TIG 2

OVERVIEW

Radial Diagnostic Catheter designed for optimum torque control and precise placement.

Product Features:

Enables angiography of both RCA and LCA with one catheter that can potentially:
– Eliminating a catheter exchange step
– Shorten procedure & fluoroscopic time
– Lower cost per procedure

  • Engages with simple clockwise & counter clockwise rotation
  • Soft reduces potential for vessel trauma
  • High Flexibility
  • Superior Surface Smoothness
  • Excellent 1:1 Torque Control as designed double wire stainless steel braiding
  • Large inner lumen for superior flow rates
  • Atraumatic soft tip
  • Max Pressure : 1200 PSI / 84 bar
  • Guidewire Compatibility : 0.038”/ 0.97mm

Product Features:

Categories
Vascular Accessories

AGILE

AGILE

Guiding Catheter

OVERVIEW

AGILE guide catheter is the ideal choice of a healthcare professionals for smooth and fast angioplasty with excellent shape retention.

Product Features:

Unique Hydrophilic Coating

 

For low resistance in tortuous and calcified anatomy

Reduce vessel spasm in radial approach resulting in more patient comfort

Less trauma to the vessel wall reducing the risk of debris flowing downstream

Precise control

No stick slip effect as the primary secondary curve is not hydrophilic coated

Accurate tip positioning in ostial lesions

Superior back up support

Stainless steel Braiding enables high torque, stability and control

Excellent shape retention during the prolonged procedure time

Largest Inner Lumen

Better contrast flow, also in combination with kissing balloon technique

Wide inner lumen offers expanded device compatibility for large profile devices and enables downsizing.


Wide range of curves available in all french

Categories
Balloons

Yukon NC Prime

Yukon NC Prime

Engineered To Outperform In Resistant Lesions

OVERVIEW

– Yukon SC Prime is a hydrophilic coated balloon catheter engineered to improve crossability and pushability to treat any lesion. 

– Delivers exceptional performance needed to succeed in demanding cases
– Seamless tip design from balloon to tip for efficient energy transfer.

LESION ENTRY PROFILE (mm)

TECHNICAL SPECIFICATIONS

ORDERING MATRIX

Categories
Balloons

Yukon SC Prime

Yukon SC Prime

Designed To Overcome The Anatomical Intricacies

OVERVIEW

– Yukon SC Prime is a hydrophilic coated balloon catheter engineered to improve crossability and pushability to treat any lesion. 

– Delivers exceptional performance needed to succeed in demanding cases
– Seamless tip design from balloon to tip for efficient energy transfer.

LESION ENTRY PROFILE (mm)

TECHNICAL SPECIFICATIONS

ORDERING MATRIX

Categories
Balloons

NIC Nano Hydro

NIC Nano Hydro

World’s Smallest Non-Compliant CTO Balloon

OVERVIEW

NIC Nano Hydro is the World’s smallest Non-compliant CTO Balloon with a diameter of 0.85 mm and an Ultra -low Crossing Profile of 0.019”. NIC Nano Hydro is a CE Marked access device engineered to successfully cross through Balloon Uncrossable lesions. The combination of an Ultra-low Profile, Excellent Trackability and Hydrophilic Coating are key to a successful treatment of tightest lesions and CTO’s.

THE ULTIMATE TOOL IN YOUR CTO ARMAMENTARIUM

INDICATIONS FOR USE

Successful treatment CTO’s (Chronical Total Occlusions).

The balloon of choice to gain access for Plaque Modification Devices in challenging lesions.

Re- crossing of stented side branches.

 

ORDER INFORMATION

Categories
Balloons

OPN NC

OPN NC

Ultra High Pressure Plaque Modification Device

OVERVIEW

OPN NC is a unique Swiss made CE Marked Plaque Modification Device designed to perform in all complex lesions at Ultra-High Pressures. OPN NC utilizes Ultra-High Pressures to cause Calcium fracture or oppose Calcium to arterial wall.OPN NC is designed with a dual layer technology to withstand Ultra-High Pressures which leads to uniform expansion even at pressures as high as 45 Bars.

DESIGNED TO PERFORM IN ALL COMPLEX LESION SUBSETS

LINEAR COMPLIANCE AND UNIFORM EXPANSION

OPN NC grows less than 10 % until the Rated Burst Pressure of 35 Bars

OPN NC has a Uniform Expansion at pressure of 45 Bars as well, with no Dog Boning seen

OPN NC causes minimal perforations and no edge dissections

INDICATIONS FOR USE

For Plaque Modification in moderate to severely calcified lesions

In combination with Rotablation for large vessel diameters

Successful treatment of ISRs

DES Under Expansion due to severe calcification

Neo atherosclerosis with Calcification

Two layers of DES in combination with DEb

ISR CTo

1.5 mm smallest non compliant balloon for severely calcified coronary arteries

TIPS AND TRICKS: REMEMBER WHILE USING OPN NC

Avoid Polymer Sleeve wires and Use Extra Support Guidewires for accessing the lesions

For Pre Dilatation /treatment of DES ISR use 0.5 mm lesser diameter balloon than the Reference Vessel Diameter

For Post Dilatation 1:1 Balloon to Vessel ratio is recommended

Slow increment of pressures ( above 20 atm, increase progressively , approx. 5 atm/ 10-20 sec) for adequate luminal gain

Allow Balloon “to work/ deploy”(slight decrease in pressure due to expansion of the balloon) before increasing the pressure

Remember to De-air the Balloon and choose the correct size for optimal results at Ultra High Pressures.

OPN ID (Ultra High Pressure Inflation Device)

*OPN NC should be used with OPN ID (Swiss made Inflation Device) with a working limit of 55 ATM for optimum utilisation of the device
 
Pressure Range 55 ATM
Manometer Resolution 5 ATM
Categories
Stents

Racer CC #3

Racer CC

Sirolimus Eluting Coronary Stent System

Thin Structural Design Concomitating with Greater Deliverability

Ideal Strut Thickness

Racer CC is designed with thinner struts to provide the healing advantage associated with minimal vessel injury and better endothelialisation.

Greater Deliverability

Racer CC with its ideal strut thickness offers optimal strength, flexibility and pushability thus ensuring precise deployment

Enhanced Biocompatibility

The trusted stent platform of Racer CC has been steadily optimized with thinner struts and cell design offering better long-term outcomes

In this unique long term analysis at 10 years, Yukon has shown the lowest rate of Definite/ Probable Stent Thrombosis with a significant risk reduction than Cypher (50%) and numerically lower TLR rates as compared to Xience (29%) while maintaining the similar efficacy.

Comparison of clinical outcomes at 10 years in patients treated with new-generationBP-SES versus new-generation PP-EES versus early generation SES.

Technical Data

PRODUCT MATRIX / ORDERING INFORMATION*

COMPLIANCE CHART

Categories
Stents

Racer CC #2

Racer CC

Sirolimus Eluting Coronary Stent System

Thin Structural Design Concomitating with Greater Deliverability

Ideal Strut Thickness

Racer CC is designed with thinner struts to provide the healing advantage associated with minimal vessel injury and better endothelialisation.

Greater Deliverability

Racer CC with its ideal strut thickness offers optimal strength, flexibility and pushability thus ensuring precise deployment

Enhanced Biocompatibility

The trusted stent platform of Racer CC has been steadily optimized with thinner struts and cell design offering better long-term outcomes

In this unique long term analysis at 10 years, Yukon has shown the lowest rate of Definite/ Probable Stent Thrombosis with a significant risk reduction than Cypher (50%) and numerically lower TLR rates as compared to Xience (29%) while maintaining the similar efficacy.

Comparison of clinical outcomes at 10 years in patients treated with new-generationBP-SES versus new-generation PP-EES versus early generation SES.

Technical Data

PRODUCT MATRIX / ORDERING INFORMATION*

COMPLIANCE CHART