Hydrophilic guide wire covered with polyurethane contains tungsten and a hydrophilic polymer coating for complete, low friction manoeuvrability.
Indicated for use of standard angiography in coronary and peripheral cases, catheterization, peripheral angioplasty and stenting (with or without an exchange wire), and sub intimal angioplasty in small, standard or large proximal or distal vessels.
Product Features:
Good Trackability & Traceability Nitinol alloy core resists kinking in tortuous anatomy, allowing for easier and faster tracking.
Excellent Torque Control Elastic material and integrated design allows 1:1 torque response to deliver the guidewire into the target vessel quickly
Durable & Lubricant Performance Hydrophilic coating offers a durable and smooth approach possible even in tortuous vessels.
Preeminent Visualization Tungsten blended polymer ensures great visualization under X- ray
Sheaths are intended to be inserted percutaneously into a vessel to facilitate the entire interventional procedure.
Product Features:
A rotating suture collar that facilitates greater procedural flexibility. It stays in place better and allows more patient movement.
A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer for improved bendability and support. It is also less prone to kinking, cost-effective and reliable.
Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered. This results in smooth insertions and may cause less damage upon entry.
Unique cross-cut valve which maintains uncompromised hemostasis to avoid bleeding & air aspiration.
Smooth sheath-to-dilator transition and optimally tapered dilator enable to reduce penetration resistance.
Extremely thin radiopaque wall with anti-kinking sleeve for excellent catheter handling.
Dilator internal tip diameter equals to mini guidewire external diameter.
Radial Diagnostic Catheter designed for optimum torque control and precise placement.
Product Features:
Enables angiography of both RCA and LCA with one catheter that can potentially: – Eliminating a catheter exchange step – Shorten procedure & fluoroscopic time – Lower cost per procedure
Engages with simple clockwise & counter clockwise rotation
Soft reduces potential for vessel trauma
High Flexibility
Superior Surface Smoothness
Excellent 1:1 Torque Control as designed double wire stainless steel braiding
AGILE guide catheter is the ideal choice of a healthcare professionals for smooth and fast angioplasty with excellent shape retention.
Product Features:
Unique Hydrophilic Coating
For low resistance in tortuous and calcified anatomy
Total length is 100 cm in which 7 cm uncoated distal end area allows primary & secondary curve to give optimal support and 25 cm uncoated proximal end of the catheter stays outside for optimal control of the catheter. Also it increases the grip outside the body for 1:1 torque.
Reduce vessel spasm in radial approach resulting in more patient comfort
Less trauma to the vessel wall reducing the risk of debris flowing downstream
Precise control
No stick slip effect as the primary secondary curve is not hydrophilic coated
Accurate tip positioning in ostial lesions
Superior back up support
Stainless steel Braiding enables high torque, stability and control
Excellent shape retention during the prolonged procedure time
Largest Inner Lumen
Better contrast flow, also in combination with kissing balloon technique
Wide inner lumen offers expanded device compatibility for large profile devices and enables downsizing.